Funexti Human connection program
A Windows program that reads check-ins from attendance devices, attendance databases and file folders in your network and sends them to Funexti Human.
For Windows 10 and 11, 64-bit, about 52 MB. The installer is not digitally signed yet, so Windows may warn before it runs. The SHA-256 of each release is in the update manifest of the program.
What it is and when to use it
The connection program runs on a Windows computer inside your network. It reads check-ins and the list of users from attendance devices, from the database of another attendance program, or from CSV and Excel files, and sends them to Funexti Human over HTTPS. One installation can read several sources and send each one to one or more devices in Funexti Human.
Use it when an attendance device cannot send to the internet by itself, or when your attendance software keeps its check-ins in a database or exports files. A device or system that has its own cloud or API sends directly to Funexti Human instead, by webhook or push: a ZKTeco or Ronald Jack terminal with the cloud server option, or a Hanet camera.
Tested on a real device: ZKTeco F21. Other devices that use the ZKTeco protocol on port 4370 may work but are not tested yet; when a device stores its records in a layout the program does not know, the program says so instead of guessing.
Requirements
- A computer with Windows 10 or Windows 11, 64-bit, that stays on. Its clock must be correct.
- A Windows administrator account to install the program. Day-to-day use needs no Windows rights.
- The computer can reach the attendance devices or the database in your network, and Funexti Human on the internet over HTTPS.
- Free disk space: about 65 MB a day for 5 devices with 10,000 employees each, about 23 GB for one year.
- Check-ins are kept on this computer for one year by default, then each month is archived to a ZIP file.
Install
Download the installer
Download the installer with the button at the top of this page on the computer that will run the program.
Run it as an administrator
Open the file and accept the Windows administrator prompt. If Windows SmartScreen says Windows protected your PC, select More info, then Run anyway. Java is included, nothing else needs to be installed.
Choose the data folder
On a first installation the Data folder page asks where the settings, the encrypted keys and passwords, the console accounts, the check-ins and the logs are kept. The default is under ProgramData. Choose a new or empty folder on a local NTFS fixed drive of this computer: not the root of a drive, not a network, removable or disc drive, not inside a user profile or the program folder, and not a link. The data folder of an earlier installation of the program is used as it is.
Create the first console administrator
The Console administrator page asks for a user name and a password of at least 10 characters. This account belongs to the program only; it is not a Windows account.
Let it run in the background
The program is installed as a background task that starts with Windows, so it keeps sending check-ins when nobody is signed in. Two shortcuts are added to the Start menu: Funexti Human connection program, which opens the console, and Reset console password.
Open the console
The shortcut opens the console in your browser at http://127.0.0.1:47123. It works on this computer only and is never open to the network.
Add the device in Funexti Human
Open the attendance devices
In Funexti Human, go to Settings, then Attendance devices. Attendance devices are part of the Premium and Plus plans.
Register a device
Select Register device and choose Connection program as the connection. Register one device for each attendance device, database or folder whose check-ins you want to tell apart.
Choose how entries are read
On the device page, Direction of entries tells Funexti Human what a record means when the source leaves the direction to it: Alternate, Device keys, Entrance gate, Exit gate or Presence only.
Copy the device id and the device key
The device key is shown once, right after you register: copy it now. The device id is on the Connection tab of the device, with a copy button. If the key is lost, rotate it from the device menu and type the new key in the console.
Add a source in the console
Sign in to the console
Open the console from the Start menu and sign in with your console account.
Add a source
On the Sources page, choose Add attendance device, Add database source or Add file folder.
An attendance device
Type the address of the device in your network, the port, usually 4370, the protocol, TCP or UDP for older firmware, the comm key if the device has one, and the time zone of the device clock. For In and out, choose Decided by Funexti Human, or From the key pressed and type the key values for in and for out.
A database
Choose SQL Server, PostgreSQL, MySQL or MariaDB, or a Microsoft Access file. Pick the table or view and the columns for the person, the time and the direction. The program only reads; a database account that can only read is recommended, and the console warns when the account can write. To combine several tables, ask your database administrator for a view.
A file folder
Choose the folder and the name pattern of CSV or Excel files, then the columns. A file is read once it has not changed for 2 minutes.
Add the Funexti Human device
Select Add a device and type the device id and the device key you copied in Funexti Human.
Test the connection
Test connection reads the source once and checks the key with Funexti Human. The reasons of a failed test are listed below it.
Enable the source
Select Enable. The first sync sends the check-ins of the last 7 days, or from the start date you set.
After the first sync
Follow the next sync
The page of each source shows when the next sync runs, with a countdown, and what happened lately. An attendance device is read every 60 seconds by default.
See the check-ins
The Check-ins page lists every check-in read from the sources, with the result on each Funexti Human device: Applied, Already on Funexti Human, Waiting for a link, Rejected with the reason, or Not sent.
Link device users to employees
In Funexti Human, open the device and its Device users tab, then link each user of the device to an employee. Suggestions by employee code are ready to accept. Check-ins of a user who is not linked yet are kept and applied once you link them.
Console accounts
An Administrator changes sources, settings and accounts. A Viewer can only look. Administrators add, change and remove accounts on the Console accounts page; everyone changes their own password from the account menu.
Forgotten password: on the computer of the program, open Reset console password from the Start menu. Windows asks for administrator approval, then you choose the account and type the new password twice. After a silent installation, the same tool creates the first administrator.
After several wrong passwords in a row, the next try of that user name has to wait, up to 60 seconds.
Backup and restore
The Backup and restore page is for administrators and asks for your console password each time.
Export downloads one file with every source, Funexti Human device and setting, and the record of which check-ins were already sent. Device keys, comm keys and database passwords inside it are encrypted with an export password of at least 12 characters. Console accounts and check-ins are not in the file.
Import uploads that file, shows what will change, then keeps or replaces the sources you already have. With a wrong or forgotten export password the file still imports: the sources stay paused until you type their keys and passwords again.
Each month past the retention period is archived to a ZIP file in the data folder before it is removed from the program. Download or delete the archives on the same page.
Updates and uninstall
When a new version is published, the console shows Update available in the menu. An administrator installs it from there; settings, keys and check-ins are kept.
To uninstall, use Apps in the Windows settings. The uninstaller asks whether to keep the data folder: keep it if you will install the program again on this computer.
Troubleshooting
The sign-in page says the program is not running
Open Task Scheduler, find the task Funexti Human connection program and run it. If it stops again, open Event Viewer, then Windows Logs, Application, and look for the source Funexti Human connection program: the reason is written there.
The test fails
Read the reasons below the test. For a device, check the address, the port, the comm key and the firewall of this computer. For a database, check the server, the database name and the account. When Funexti Human refuses the key, rotate it on the device page and type the new key in the console.
Check-ins are waiting for a link
The device user is not linked to an employee yet. Link it on the Device users tab of the device in Funexti Human; the waiting check-ins are applied on their own.
Check-ins have a wrong time
The program sends the time the device recorded. Correct the clock on the device, or use Set the attendance device clock in the console. Check-ins already sent with a wrong time are corrected in Funexti Human with a regularization.